AC4LESS Dispatch Active

(626) 409-2552

Refrigerant specialists · Baldwin Park & the San Gabriel Valley

R-22 (Freon) AC Repair, Leak Detection & Recharge in Baldwin Park

If your air conditioner was installed before about 2010, it probably runs on R-22 — the refrigerant most people call Freon. R-22 systems are still legal to own, run and repair. What changed is supply: U.S. production and import of R-22 ended on January 1, 2020, so every pound used today is reclaimed or from existing stock. That makes finding and fixing the leak before recharging more important than ever.

  • Existing R-22 systems can still be used and repaired — no replacement or conversion is required
  • No new R-22 has been produced or imported in the U.S. since January 1, 2020
  • Service now relies on reclaimed and previously produced R-22, so price and availability can change
  • Refrigerant must be recovered, never vented, and handled only by EPA Section 608–certified technicians

Signs your R-22 system is low on refrigerant

  • Vents blowing cool-ish or warm air on hot afternoons
  • Ice on the copper suction line or indoor coil
  • Hissing or bubbling sounds near the lines
  • The system runs almost nonstop but the house won't cool down
  • Electric bills climbing with no change in usage
  • Oily residue at a fitting or coil — a common leak sign

How we service an R-22 system

  1. 1

    Confirm the refrigerant and system condition

    We read the nameplate, check the age and condition of the compressor and coils, and measure pressures and temperatures before recommending anything.

  2. 2

    Find the leak

    We locate the leak with an electronic leak detector, bubble solution and, when needed, a nitrogen pressure test — instead of guessing and adding refrigerant.

  3. 3

    Repair and pressure-test

    Leaking fittings, Schrader cores, coils or line sections are repaired, then the system is pressure-tested to prove it holds.

  4. 4

    Evacuate

    We pull a deep vacuum to remove air and moisture, which protect the compressor and keep the system efficient.

  5. 5

    Recharge to specification

    The system is charged with reclaimed R-22 to the manufacturer's specification, checked against superheat or subcooling — never mixed with another refrigerant.

  6. 6

    Verify cooling

    We confirm the temperature split, amperage and pressures, and walk you through what we found and what was done.

R-22 vs. R-410A at a glance

R-22 vs. R-410A refrigerant specifications
PropertyR-22R-410A
Chemical designationHCFC-22 (chlorodifluoromethane)HFC-410A: 50% R-32 / 50% R-125 blend
Common namesFreon, R-22Puron and other brand names
ASHRAE safety classA1 (non-flammable)A1 (non-flammable)
Ozone depletion potential0.0550
Global warming potential (AR4, 100-yr)1,8102,088
Boiling point at sea level−40.8 °C (−41.4 °F)about −51 °C (−60 °F)
Saturated pressure at 70 °Fabout 121 psigabout 200 psig
Compressor oilMineral oil or alkylbenzenePOE (polyolester), absorbs moisture
How it's chargedAs vapor or liquidAs liquid (it's a blend)
Typical systemsInstalled before about 2010Installed about 2010–2025
U.S. statusNo new production or import since Jan 1, 2020No new residential split systems built since Jan 1, 2025; still serviceable

Pressures are approximate saturated values and vary with temperature. Always follow the equipment manufacturer's charging specifications.

Running a newer system? See our R-410A (Puron) refrigerant service page.

Repair or replace an R-22 air conditioner?

If the compressor is healthy and the leak is small and repairable, fixing an R-22 system can buy you several more cooling seasons. If the system is 15 or more years old, has a major leak in the coil, or needs a compressor, replacement is usually the better investment because you'll keep paying a premium for R-22 every time it's serviced.

We'll price both options side by side. You can also compare equipment levels with our Good-Better-Best equipment explorer or read about AC installation and system replacement.

R-22 refrigerant FAQs

Is R-22 refrigerant still legal to use and repair?

Yes. You can keep using and repairing an existing R-22 air conditioner, and the EPA doesn't require you to replace or convert it. What ended on January 1, 2020 was U.S. production and import of new R-22, so service now relies on reclaimed and previously produced refrigerant.

What is the difference between R-22 and R-410A?

R-22 (HCFC-22) is a single refrigerant that contains chlorine and depletes ozone. R-410A is a chlorine-free blend of R-32 and R-125 that runs at much higher pressure and uses POE oil instead of mineral oil. The two are not interchangeable — see the comparison table above.

Can you put R-410A in my R-22 system?

No. R-410A runs at far higher pressure and needs a different compressor oil, so it can't be added to an R-22 system, and refrigerants should never be mixed. Some R-22 systems can be retrofitted to an EPA-approved replacement refrigerant, which is a separate job; we'll tell you honestly whether it makes sense.

Why does an R-22 recharge cost more than it used to?

Because no new R-22 has been produced or imported in the U.S. since 2020, every pound comes from reclaimed or existing stock, and that limited supply keeps prices high. That's why we find and fix the leak first instead of just topping the system off.

Do you sell R-22 refrigerant?

No. AC4LESS provides refrigerant service — leak repair, recovery and recharge by our technicians. Federal rules restrict refrigerant handling to EPA Section 608–certified technicians, and we don't sell refrigerant to the public.

How do I know if my AC uses R-22?

Check the nameplate on the outdoor unit — it lists the refrigerant type and charge. Most central air systems installed before about 2010 use R-22. If the label is faded, we can confirm it during a service visit.